R410a refrigerant specifications. Jun 11, 2014 · Goodman SSX140421 - Goodman 3.
R410a refrigerant specifications Package Find R410A Refrigerant related suppliers, manufacturers, products and specifications on GlobalSpec - a trusted source of R410A Refrigerant information. 3. Below is a comparison table between R32 and the traditional R22 and R410A refrigerant options: You can see that R32 significantly differs from its predecessors in terms of environmental impact. Buy Goodman GSXN403610 3 Ton, 14. These tables are based on extensive experimental measurements. Mixtures of CFC refrigerants and conventional mineral oils generally get a rating of 3, which is the limit of acceptability. A refrigerant handling licence is required when using R32 refrigerant, and a refrigerant trading authorisation is required to acquire, possess and dispose/sell it. 4°F) Refrigerant Reference Guide 43 5th Edition 2010 R-410A Technical Guidelines Applications: Air conditioning equipment and heat pumps. Dec 18, 2024 · Refrigerant Leak Check coils tested at factory with extensive refrigerant leak check Composite Base Pan dampens sound, captures louver panels, eliminates corrosion Cabinet Air Leakage Less Than 2. Aug 9, 2024 · The US Department of Energy divided the country into 3 regions (North, Southeast, and Southwest) and established energy efficient standards for each. 05kg R410A/1. org) for the most up-to-date ratings information. 8-5 42. 0 9. The Refrigerant Gas Data table and Allowable Internal Pressure table are listed below. 3 PHYSICAL DATA UNIT SERIES 18GKP 24GKP 30GKP 36G*P, LKA 42GKP, LKA 48G*P 60G*P Compressor Type Scroll REFRIGERANT R- 410A Control TXV (R- 410A Hard Shutoff) Condenser pre-charged with R410A refrigerant. SPECIFICATIONS. The SSX14 central air Complete in Specifications R410A Refrigerant Gas, Find Details and Price about Diffierent Type of Packing Refrigerant R410A from Complete in Specifications R410A Refrigerant Gas - Chengdu Henbin Refrigeration Co. To prevent mischarging, the diameter of the service port differs from that of R22. With a lower GWP, this refrigerant is a more sustainable choice than R22 and R410A. 8 Liquid Line Valve Connection: 3/8" outside diameter Suction Line Valve Connection: 3/4" outside diameter. Dimensions: W33 3/4" x D33 3/4" x H31" Volts: 208/230 Phase: 1 Hertz: 60 Sound Rating: 76. May 6, 2011 · Goodman GSZ130601 - Goodman 5 Ton 13 SEER Heat Pump w/ R410A Refrigerant- The GSZ13 Heat Pump uses the chlorine-free refrigerant R-410A and features operating sound levels that are among the best we offer in the heating and cooling industry. × in. Feb 3, 2020 · 1 Safety Instructions R 410A refrigerant 7 1. Country of Origin R410A is an HFC blend designed for new R22 applications. Specifications: Appearance : Liquefied, colorless gas Odor : Faint ethereal odor Physical state : Gas at normal temperature and pressure Boiling point : – 48. Systems designed for R410A can take advantage of its ability to use smaller components, making it a key refrigerant for domestic and light air conditioning equipment. Locations. Oct 11, 2017 · R-410A is actually more efficient at absorbing heat then R-22. Refrigerants - Saturation Pressures vs. Oct 19, 2023 · What are A2L Refrigerants? “A2L refrigerants can be a single refrigerant or a blend of multiple refrigerants in specifics amounts,” De La Portilla says. 71 times that of R410A. Specification Sheets Consumer Literature Specifications: Refrigerant Type: R410a; Net Weight: 1. R410A Connectors: 5/16" SAE . Solstice® Refrigerants, Blowing Agents and Propellants Condenser pre-charged with R410A refrigerant. HAZARDS IDENTIFICATION Refrigerant (R-410A) 0 0 20 40 60 80 Temperature (°F) 100 120 140 R-22 R-410A 100 200 300 400 500 600 700 Product Information Freon™ 410A is a non-ozone depleting high efficiency hydrofluorocarbon (HFC) refrigerant. Split System (R410A) 16 SEER, Inverter Units 9,000 to 24,000 BTU/Hr. Pressure equalisation Code no. 8 lbs of Pro Charge R410A Refrigerant pre-blended with with UV Dye & Leak Sealant. Key Features • R410A Refrigerant • Ultra High Efficiency Fan Motor • Anti-Rust Cabinet • Self Diagnosis; Find a store near you Coils tested at factory with extensive refrigerant leak check Composite base pan dampens sound, captures louver panels, eliminates corrosion Outdoor unit pre-charged with R410A refrigerant. Specification Sheets Consumer Literature WESTRON R410a refrigerant is a Non-Ozone Depleting, Non-Toxic, Nonflammable near Azeotropic blends of two Refrigerants namely R-125 (50%) and R-32 (50%). 0TR . 78. Ideal for installation in offices and business establishments. , Ltd. 7 Injuries from swallowing liquid refrigerant 9 O_754011_5 02. Jan 7, 2015 · Goodman SSX140481 - Goodman 4 Ton 14 SEER Central Air Conditioner w/ R410A Refrigerant- The Goodman® SSX14 14 SEER Central Air Conditioner uses the environmentally friendly refrigerant R-410A and features operating sound levels that are among the best in the heating and air conditioning industry. 0 Inch H2O tested in accordance with ASHRAE Standard 193 Condenser Pre-charged with R410A refrigerant SPECIFICATIONS Condenser pre-charged with R410A refrigerant. 3 Emergency equipment 8 1. Intended for use by qualified technician only. 6 Skin contact 9 1. (UNF1/2) • Use high-tension side pressure of 5. This environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth’s ozone layer. Check out some of our refrigerant focus posts below. 0 HSPF2: 7. Specifications Condenser Dimensions: H45 1/4" x W31 3/4" x D31 3/4 " Air Handler Dimensions: H56" x W22 1/2" x D22 " Volts: 208/230 Phase: 1 Hertz: 60 EER2: 11. We will also delve into various aspects of its application, installation procedures, environmental implications, […] Dec 17, 2024 · Condenser pre-charged with R410A refrigerant. 5 Ton 14 SEER Central Air Conditioner w/ R410A Refrigerant- The Goodman® SSX14 14 SEER Central Air Conditioner uses the environmentally friendly refrigerant R-410A and features operating sound levels that are among the best in the heating and air conditioning industry. In this article, we will explore the chemical composition of R410A, its safety grades, and how it differs from traditional refrigerants. Recovery equipment includes not only the recovery/recycling machine itself, but also all equip-ment that comes into contact with the refrigerant dur-ing recovery and reclamation. If the cylinder is not returned after 6 months a lost cylinder charge will be charged at the beginning of month 7 All our Refrigerant cylinders are trackable via a unique serial number barcode. It is mainly used in air conditioning and industrial refrigeration applications. . 0 6. It Has Higher Cooling Capacity and Significantly Higher Pressure Than R-22 and Should Be Used Only In Systems Specifically Designed For R-410A. Max Working Pressure: 800PSI . 74 Temp °F R410A psig 0. Equations have been developed, based on the Martin-Hou equation of state, which represent the data with accuracy and consistency throughout the entire range of Jun 5, 2019 · Manifold gauge set is designed to meet 1/4" Standard SAE requirements for refrigerant permutation . The working pressure of R32 system is higher than R410A, but the maximum increase is not more than 2. Equations have been developed, based on the Martin-Hou equation of state, which represent the data with accuracy and consistency throughout the entire range of PRODUCT SPECIFICATIONS This unit has been designed utilizing R-410A refrigerant. Also for: 4mxw6, 4txw6. Specifications subject to change without notice. 8 lbs; Gauge Included: Yes; Compatibility: Suitable for most R410a HVAC systems; Package Includes: 1. 8 158. Refrigerant oil/oil charge ml POE /280cc ESTER OIL VG74/480 ESTER OIL VG74/480 ESTER OIL VG74 /950 Model RPG20B RPG28H RPG45B RPG45B R410 UNITS SPECIFICATIONS. One of the most prevalent refrigerants currently in use is R410A, a blend of hydrofluorocarbons (HFCs) that has gained popularity due to its efficiency and eco-friendliness compared to older refrigerants like R22. Aug 29, 2024 · The US Department of Energy divided the country into 3 regions (North, Southeast, and Southwest) and established energy efficient standards for each. SPECIFICATIONS VRF Refrigerant Leak Detection Solutions . 261-40 11. 1 Liquid Line Valve Connection: 3/8" outside diameter Suction Line Valve Connection: 3/4" outside diameter. 5 Ton Split HSU-18LTH (White Colour). Refrigerant Gas Data Critical Point Refrigerant Refrigerant R-410A SUVA AZ20 Refrigerant 25 Lb Cylinder. The majority of these refrigerants are mildly flammable (A2L) and are the subject of this paper. Jan 9, 2025 · As the demand for energy-efficient cooling systems continues to grow, so does the complexity surrounding refrigerants used in HVAC units. NOTE: Ratings contained in this document are subject to change at any time. Comes with 3 Year Compressor & 1 Year Parts Warranty. We are going to look at how to match the refrigerant oil type (POE, PAG, MO, AKB) to an air compressor type and refrigerant type (what oil for R22, R410A, R32, R134A freons, and so on) and look at refrigerant oil compatibility chart. Arkema R410A REFRIGERANT, 25LB CYLINDER. Specifications Condenser Dimensions: H45 1/4" x W31 3/4" x D31 3/4 " Air Handler Dimensions: H49 5/16" x W19 11/16" x D22 " Volts: 208/230 Phase: 1 Hertz: 60 EER2: 11. com Comparison Chart Temperature/ Pressure R-22-R-410A Condenser pre-charged with R410A refrigerant. Step 2: Turn off the Power To avoid any accidents or damage to the system, it’s important to turn off the power to your cooling system. ahridirectory. Harmonize Code: 3824. R410A air conditioner pdf manual download. 4kg R410A/2. 3 25 87. Please check the SEER2 site to ensure efficiency compliance for your region. Place Your Order by 1 pm for Same-Day Shipping Aug 1, 2024 · Goodman GSXN404810 - GSXN 4 Ton 14. 5 0-20 26. 4kg Type Rotary Rotary Rotary Rotary Rotary Model QXA-B102C130 QXA-B120C150 QXA-F20F050 QXA-F232F050 ATF250D22UMT MFG ZHUHAI LANDA COMPRESSOR CO LTD ZHUHAI LANDA COMPRESSOR CO LTD ZHUHAI LANDA COMPRESSOR CO LTD ZHUHAI LANDA COMPRESSOR CO LTD HITACHI National Refrigerants, Inc. 3 SEER2 Energy-Efficient Split System Air Conditioner w/ R410A Refrigerant- <b>To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. 100 lb. Condenser Dimensions: H35" x W33 3/4" x D33 3/4 " Air Handler Dimensions: H50 1/2" x W21" x D21 11/16 " Volts: 208/230 Phase: 1 Hertz: 60 Composed by combining two different refrigerants, R32 and R125, R410a was introduced as a replacement for older refrigerants. 3MPa·G or over. 2 10 62. 5 7. 0% At 1. Any perceptible change of color, clarity, or surface finish changes the rating to 1. Both the neat refrigerant and a mixture of lubricant and refrigerant (50/50 volume ratio) were tested. Dimensions: W35 3/4" x D35 3/4" x H51" Volts: 208/230 Phase: 1 Hertz: 60 Sound Rating: 75. 7 Liquid Line Valve Connection: 3/8" outside diameter Suction Line Valve Connection: 3/4" outside diameter. Comparative analysis of the characteristics of R410A and R32. R-13B1 is an ozone-depleting refrigerant, and production has ceased as Temperature and pressure chart for refrigerants R22, R410A, R12, R134A, R401A, R409A, R502, R404A, R507A, R408A and R402A. PHYSICAL ATTRIBUTES ODP: 0 GWP: 1725 Class/ Type: Zeotropic blend (A1) Refrigerant R410a 25lb Cylinder Application: R-410A has replaced R-22 as the preferred refrigerant for use in residential and light commercial air-conditioning and heat pump systems. Refer to the Safety Data Sheet*. 0000: Note: B92-911 returnable cylinders are subject to deposit unless empty cylinder is returned at time of purchase. 7 A1-10 36. Industry leading Features / Benefits R410A is an HFC blend designed for new R22 applications. 3 34. R410A was not designed to retrofit existing R22 systems but many manufacturers have used its superior qualities to build products with higher efficiencies. 0 Liquid Line Valve Connection: 3/8" outside diameter Suction Line Valve Connection: 7/8" outside diameter Specification Sheets Consumer Literature Goodman GSZ140481 - GSZ 4 Ton 14 SEER Energy-Efficiency Split System Heat Pump w/ R410A Refrigerant- Goodman GSZ14 Split Heat Pump 14 SEER & HSPF, Single Stage, 4 Ton Benefits Energy-efficient compressors are designed to efficiently deliver indoor comfort, possibly saving on monthly energy costs. Use a polyol ester (POE) oil. refrigerant. What that means is that your air conditioner won’t work as hard and your home will stay cooler all the while saving on your power bills. 0TR, 5. As a hydrofluorocarbon (HFC) refrigerant, R410a does not contain chlorine that has ozone depleting properties. Product Overview: SensAC VRF Refrigerant gas leak detector with NDIR sensor technology meets the need for a cost-effective and reliable solution to continuously monitor and detect refrigerant gas in occupied space in commercial buildings. 3 decibels high stage, 61. 410A refrigerant (ASHRAE designation: R-410A [50/50]), have been developed and are presented here. GSZB 5 Ton 14. 850 lb. Presented at the ASHRAE Annual Meeting, 23-26 Jun 2019, Kansas City, Conference Paper KC-19-C018). Prime Refrigerant R410A, also known as AZ20, is a blend of HFC refrigerants now commonly used for air conditioning applications. 0TR, 7. Outdoor units. The SSX14 central air Aug 1, 2024 · The US Department of Energy divided the country into 3 regions (North, Southeast, and Southwest) and established energy efficient standards for each. Specifications: --Specifications-- Application: R404a, R410a, R22 Refrigerant . Condenser Dimensions: H51" x W35 3/4" x D35 3/4 " Air Handler Dimensions: H55 1/2" x W24 1/2" x D21 11/16 " Volts: 208/230 Phase: 1 Hertz: 60 Based on its vapor pressure characteristic of refrigerant, the 410A high pressures refrigerant gas systems should be designed in accordance with the safe internal working pressure of lineset tubing. 5 Liquid Line Valve Connection: 3/8" outside diameter Suction Line Valve Connection: 3/4" outside diameter Refrigerant (R-410A) Replacement for R-13B1: Properties and Operating Characteristics of Freon™410A Refrigerant in Very Low Temperature Systems Technical Information Freon™ 410A provides comparable performance to R-13B1 in most very low temperature, (VLT) applications. 410A operates at a much higher pressure than R-22, between fifty to sixty percent higher. 0 Inch H2O tested in accordance with ASHRAE Standard 193 Condenser Pre-charged with R410A refrigerant. Burst Pressure: 4000PSI . 1 R410A Specification 7 1. Specification Sheets Consumer Literature PRODUCT SPECIFICATIONS Split System Heat Pump: N4H4 428 14 5203 05 Specifications subject to change without notice. May 2, 2023 · Near azeotropic HFC blend with a zero ODP designed to replace R-22 in many applications such as unitary A/C, chillers, and some refrigeration. Dimensions: W33 3/4" x D33 3/4" x H27" Volts: 208/230 Phase: 1 Hertz: 60 Sound Rating: 76. Subject: Forane 410A Spec Sheet Keywords: Forane 410A, r-410A, refrigerant, HVAC, HVACR, HCFC refrigerant, blend Jul 25, 2024 · R410A refrigerant is a commonly used type of refrigerant in air conditioning and heat pump systems. 3 SEER2 Energy-Efficient Split System Heat Pump w/ R410A Refrigerant Product Features Energy-efficient R410A is the leading HFC refrigerant for replacing R-22 in positive displacement residential and light commercial air-conditioning and heat pump systems. 03. With its 13 SEER rating, the GSZ13 will help reduce energy consumption throughout the life of the system compared to units with a lower SEER. Range N –40/+10 Dec 17, 2024 · Condenser pre-charged with R410A refrigerant. A2Ls have a lower flammability rating compared to A3 refrigerants such as hydrocarbons, propane, and isobutane. Item # 505189 | Arkema Part # FORANE 410A Product Overview Documentation Specifications More Related Terms . Technical: - Available in 90-240VAC or 24VAC/DC supply voltages Condenser pre-charged with R410A refrigerant. 56kg R410A/0. R410A was not designed to retrofit existing R22 systems and should be used only in systems specifically designed for R-410A. 8 lb R410a Refrigerant Refill Kit with Gauge. Product Description: Haier AC 1. 1,450 lb. Specifications. R-410A is chlorine-free to help prevent damage to the ozone layer. Always refer to the AHRI directory (www. 3 SEER2 R410A Two-Stage Heat Pump Condenser RP14AZ36AJ2NA 10 year warranty on parts & compressor (registration required) High-efficiency two-stage scroll compressor Coils tested at factory with extensive refrigerant leak check Inverted reversing valve for faster heat transfer with gravity assist shifting & reduced joint stress Swept wing fan technology for quieter Aug 1, 2024 · This R410A unit is no longer manufactured as per the AIM Act of 2020. R410A is an HFC refrigerant that was developed as a replacement for ozone-depleting substances such as R22. In addition, it has a higher capacity than R22, which means it can handle more heat transfer than other refrigerants. 5 0 48. Also for: Rxs-g2v1b. 9 0. A rating of 0 indicates no perceptible change in appearance. Connection inlet × outlet in. 6 116. 421 41 5106 05 12/08/16 EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R-410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1-phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on all models S Filter-Drier supplied with every unit for field installation Refrigerants: National®: HFC: R410A Looking for something else? Choose a Refrigerant R11 R12 R22 R23 R123 R124 R134a R290 R401A R401B R402A R402B R403B R404A R407A R407F R407C R408A R409A R410A R417C R422B R422D R454B R438A R448A R449A R450A R452A R500 R502 R507 R508B R513A R600a R1233zd R1234ze R1234yf GEBKİM İhtisas OSB, Fatma Börü Cd. 5 decibels low stage Liquid Line Valve Connection: 3/8" outside diameter Suction Line Valve Connection: 7/8" outside diameter. EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1-phase, 60 Hz REFRIGERATION CIRCUIT Copeland compressors on all models Filter-Drier supplied with every unit for field installation Copper tube/aluminum fin coil Eliwell R410A Refrigerant is widely used as a refrigerant in many air conditioning applications, usually packaged in pink color cylinders. kg R410A/0. Differences Between R32, R22 and R410A Refrigerant Gases. Item Specification; ASHRAE # R-410A: Class: HFC: Refrigerant Type: Blend: Typical Lubricant: POE: Replaces: CFC R-22: Notes: High pressure, high efficiency 410A refrigerant (ASHRAE designation: R-410A [50/50]), have been developed and are presented here. Dimensions: W33 3/4" x D33 3/4" x H35 " Volts: 208/230 Phase: 1 Hertz: 60 Sound Rating: 74. Equipment, therefore, must be designed to handle R-410A. Check with Climalife regarding the viscosity of the oil selected for your application, and the miscibility with the fluid under consideration. ? Low Voltage Operation: Air Conditioner can work at without interruption even the Voltage drop as low as 150V View and Download Trane R410A owner's manual online. Refrigerant Focus #1: R-32; Refrigerant Focus #3: R-1234ze; Refrigerant Focus #4: R-407A Dec 18, 2024 · • Refrigerant Leak Check coils tested at factory with extensive refrigerant leak check • Composite Base Pan dampens sound, captures louver panels, eliminates corrosion • Cabinet Air Leakage Less Than 2. USE ONLY IN A/C SYSTEMS ORIGINALLY DESIGNED FOR REFRIGERANT R410A. 6 5 55. ) R410A HFC 72. 2 Personal protective equipment 8 1. No. Page 8 R410A in detail R410A is a Zeotropic blend of two refrigerants R32 50% R125 50% The phase change of R410A Pressure Sub-Cooling - Compression mixtures takes place at [bar] - Condenser an almost constant temperature - Expansion - Evaporation during the liquefaction or evaporation Dec 25, 2023 · R410A is a modern refrigerant that has gained popularity in recent years due to its superior performance and environmental benefits. Gauges are not included with purchase and are available sold separately. You can’t just use any type of refrigerant oil, as you may well know. The refrigerant name R410A is indicated on the visible place of the outdoor unit of the air condi- tioner using R410A as refrigerant. They also have a lower toxicity rating than B series refrigerants such as R410A is a non-flammable HFC blend refrigerant, developed for use in air conditioning equipment, specifically designed for R410A. 09MPa·G or over. volume of refrigerant/lubricant solution was heated in the presence of copper, steel, and aluminum coupons in an oven for 14 days at 175 °C (347 °F) or 200 °C (392 °F) for 14 days. R410A is the leading HFC refrigerant for replacing R-22 in positive displacement residential and light commercial air-conditioning and heat pump systems. Genetron® 410A (a near-azeotropic mixture of HFC-32/HFC-125) has been developed by Honeywell to serve as a long-term, non-ozone depleting energy efficient replacement for Genetron® 22 (HCFC-22) in a variety of new-equipment applications. com | 4 EPA’s Significant New Alternatives Policy (SNAP) Program is approving new refrigerants that adhere to these lower GWP limits. It is a zeotropic but near- azeotropic mixture of difluoromethane (CH 2 F 2 , called R-32) and pentafluoroethane (CHF 2 CF 3 , called R-125). honeywell. 1953-25 22. 5 02 27. Our solvents feature very low interference peaks in the elution range of target analytes and the highest specifications on the market with extensive quality control testing. R-410A Composition: (R-32 / 125) • (50 / 50 wt%) Application: Air conditioning equipment and heat pumps. 5 Eye injuries 9 1. Freon™ 410A has higher cooling capacity and operating pressures than R-22 for new equipment specifically designed for R-410A Refrigerant (R-410A) Replacement for R-13B1: Properties and Operating Characteristics of Freon™410A Refrigerant in Very Low Temperature Systems Technical Information Freon™ 410A provides comparable performance to R-13B1 in most very low temperature, (VLT) applications. Dimensions: W33 3/4" x D33 3/4" x H25" Volts: 208/230 Phase: 1 Hertz: 60 Sound Rating: 75. cantas. 5TR, 10. R32 refrigerant, and the systems designed for it, present significant changes to the service tools, working practices, component standards and workplace safety considerations Mar 29, 2021 · Buy R410A AC Refrigerant Charging Hoses, 70" R410A HVAC Charging Hose Set with 1/4" Male and Female 800PSI Working Pressure for R410A R22 R134A R12 R502 Air Condition System Maintenance: Air Conditioning Line Repair Tools - Amazon. Its composition comprises: HFC-125 (50%), HFC-32 (50%). 3 SEER2 Condenser, R-410A Refrigerant. Dimensions: H35" x W33 3/4" x D33 3/4 " Volts: 208/230 Phase: Single Hertz: 60 Sound Rating: 74. 5 Liquid Line Valve Connection: 3/8" outside diameter Suction Line Valve Connection: 7/8" outside diameter UNDERSTANDING A2L REFRIGERANTS | www. Jun 11, 2014 · Goodman SSX140421 - Goodman 3. Gauge Reading: PSI . 3 30 96. 4 First aid when using R410A, immediate measures 8 1. 661 Kenyon Avenue Bridgeton, New Jersey 08302 FOR MORE INFORMATION CALL: IN CASE OF EMERGENCY CALL: (Monday-Friday, 8:00am-5:00pm) CHEMTREC: 1-800-424-9300 1-800-262-0012 2. Before adding any Prime Refrigerant R410A, also known as AZ20, is a blend of HFC refrigerants now commonly used for air conditioning applications. 5 0. Refrigerant R410a 10kg No More Cylinder Deposits - Rent FREE for 6 months. 6%, which is equivalent to the pressure requirement of R410A system, and R32 system exhausts Compared with R410A, the temperature rises Pre-charged with R410A refrigerant. Heat pumps with R-410A refrigerant provide a collection of features unmatched by any other family of equipment. 8 03 2) 34. 2020 5 Dec 16, 2020 · Our refrigerant focus series consists of deep dives into the history, properties, suitable applications and pros and cons of some of today’s common refrigerants. Coils tested at factory with extensive refrigerant leak check Composite base pan dampens sound, captures louver panels, eliminates corrosion Outdoor unit pre-charged with R410A refrigerant. 8 Liquid Line Valve Connection: 3/8" outside diameter Suction Line Valve Connection: 7/8" outside diameter Specification Sheets Consumer Literature Dec 8, 2024 · Most modern systems utilize R410A, but it’s always a good idea to double-check the manufacturer’s specifications to ensure you are using the correct refrigerant. Hose Length: 60 inch . 9 2088-15 31. Condenser Dimensions: H25" x W33 3/4" x D33 3/4 " Air Handler Dimensions: H42 1/2" x W17 1/2" x D21 11/16 " Volts: 208/230 Phase: 1 Hertz: 60 R410A R410A 01 23. W. 8 lb canister of R410a refrigerant; Easy-to-read gauge; Maintain your air conditioning system with ease using the 1. It operates at a much higher pressure and capacity than R-22. 6kg R410A/1. Table 1. org) for The R410A refrigerant is a 50:50 mixture of R32 and R125. R-410A is a refrigerant used in air conditioning and heat pump applications. GSZB 3 Ton 14. Stability USE: Refrigerant Gas DISTRIBUTOR: National Refrigerants, Inc. 5 Ton 14. com FREE DELIVERY possible on eligible purchases Specifications subject to change without notice. Specification Sheets Confirm the used refrigerant name, and use tools and materials exclusive for the refrigerant R410A. Some examples of EPA’s proposed SNAP 26 include: Nov 15, 2024 · To determine if your air conditioning or heat pump system uses R410A refrigerant, you can begin by checking the manufacturer’s specifications or labels. Webb Company is the largest industrial equipment supplier with 16 areas of expertise including Plumbing, Heating, HVAC, Refrigeration, PVF, Building Controls, Propane Gas Equipment, Water Systems, High-Purity Process Components, Industrial PVF Specialties, Thermoplastic Piping Coils tested at factory with extensive refrigerant leak check Composite base pan dampens sound, captures louver panels, eliminates corrosion Outdoor unit pre-charged with R410A refrigerant. 1. Hose Connectors: 1/4" SAE . Unlike R22, R410A is non-ozone depleting and low in global warming potential (GWP). DO NOT MIX WITH A be caused by charging with contaminated refrigerant, cross contamination (the mixing of R-410A with other refrigerants) should be avoided during recovery and recycling. 3 Electronic scale Dec 20, 2024 · RHEEM 3 Ton Rheem 14. Refrigerant piping. Temperatures Temperature and pressure diagram for constant boiling refrigerants - imperial and SI units. It has a higher cooling capacity than R-22 and is significantly higher in pressure. For refrigerant piping, use clean, pressure-proof parts/materials specifically designed for R410A. 3 SEER2 Energy-Efficient Split System Heat Pump w/ R410A Refrigerant Product Features Energy-efficient May 24, 2019 · Buy SURIEEN R410A Refrigerant AC Charging Hose Set, 60" AC Charging Hose Tube 1/4" SAE to 5/16 SAE, Fits for R410 R32 Air Conditioning and HVAC Manifold Gauge Hose Kit (4000-800) PSI (3pcs): Air Conditioning Line Repair Tools - Amazon. If a refrigeration gas refrigerant or lubricant/refrigerant solution appeared to a visual inspection. (Refer to 2. While replacement parts are available for repairs, a new unit will require replacing the entire system to support the new A2L R32 refrigerant. 8-35 14. You need a specific air compressor oil type. com FREE DELIVERY possible on eligible purchases Dec 18, 2024 · Refrigerant Leak Check coils tested at factory with extensive refrigerant leak check Composite Base Pan dampens sound, captures louver panels, eliminates corrosion Cabinet Air Leakage Less Than 2. It is developed for Medium temperature Refrigeration applications, Residential and Commercial Air-conditioning applications like small Chillers and, Heat pumps, Dehumidifiers, etc. Product Data Summary and Thermodynamic Tables 48 Refrigerant Reference Guide 7th Edition 2020 R-410A! AVAILABLE IN SIZES "REFRIGERANT Type Size R-410A Cylinder 25 lb. 8 Technical data and ordering: TCBE Thermostatic expansion valves – TUB/TUBE/TCBE Ordering TCBE, straightway, thermostatic expansion valve with bulb strap R410A Refrigerant Type Rated capacity 2) Ori˜ce no. 3 15 70 20 78. Check the Manufacturer’s Specifications. 5 °C (-55. R-410A air conditioner pdf manual download. 6-61 691. No:5/1 Dilovası/KOCAELİ Tel: (0212) 910 1260 / Fax: (0212) 225 8111 www. R-410A is a near azeotropic HFC blend. Heatcraft recommends alternative refrigerants with substantially lower GWP. Only for newly manufactured equipment, not for retrofitting R-22 systems Performance: Presures are 60% higher than R-22, therefore should be used only in new equipment Lubricant Title: Forane 410A Refrigerant Author: Arkema Inc. Specifications 1 Gauge manifold • Only for R410A • Use the existing fitting specifications. GSZB 3. 8 35 107 40 118 45 130 50 142 55 155 60 170 65 185 70 201 75 217 80 235 85 254 90 274 95 295 100 317 105 340 110 365 115 391 120 418 125 Summary New container with 1. This installment will focus on R-410A. </b><br><br> <b>Note: As of January 1, 2023 the US Department of Energy released a new SEER2 standard that provides manufacturers guidance in measuring the efficiency Take sufficient care not to allow water and other contaminations to enter the R410A refrigerant during storage and installa-tion, since it is more susceptible to contaminations than R22. Goodman technical support information, product brochures and more. It operates at higher pressures than many other refrigerants, and so cannot be used to retrofit R22 systems. R-13B1 is an ozone-depleting refrigerant, and production has ceased as Freon™ 410A Is The Leading HFC Refrigerant For Replacing R-22 In Positive Displacement Residential and Light Commercial Air-Conditioning and Heat Pump Systems. environment than other refrigerants. As shown in the refrigerant aspect comparison above, R410A refrigerant has not only a high cooling capacity per unit, enabling saving of refrigerant, but also less environmental impact than other refrigerants, and it largely contributes to weight-saving of the chiller. <br>The GSZ13 Improved and high cooling performance utilizing eco-friendly R410A refrigerant. 2 Charge hose • Only for R410A • Use pressure performance of 5. NOTE: :Ratings contained in this document are subject to change at any time. It has higher cooling capacity and significantly higher pressure than R-22 and should be used only in systems specifically designed for R-410A. Use the below service tools as exclusive tools for R410A refrigerant. R410A is not suitable for retrofitting due to higher operating pressures. 5 67. Only for newly View and Download Daikin R-410A technical data manual online. 3 SEER2 Energy-Efficient Split System Heat Pump w/ R410A Refrigerant Product Features Energy-efficient Performance of a Novel R410A Replacement in an Air-Cooled Chiller (aka Examination of a Novel R410A Replacement). Capacity : 3. With 100+ locations across the Northeast, F. Most modern systems manufactured after 2010 are designed to use R410A, and this information is typically found on the unit’s data plate or in the owner’s manual. 0 Inch H2O tested in accordance with ASHRAE Standard 193 • Condenser Pre-charged with R410A refrigerant Specifications Every air compressor needs lubricating oil. Thermophysical properties: R32 charging volume can be reduced, only 0. 3948-30 18. wybq idzm otfgg cbtj vmrcd ewjo xebgax qkwxpl mppua jfa